        <article-title>高压配电变压器常见故障分析与状态检修技术研究</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>冉华洲</string-name>
        </contrib>
        <contrib contrib-type="author">
          <string-name>聂阳</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2026</year>
        <month>3</month>
      </pub-date>
      <issue>3</issue>
      <abstract>
        <p>高压配电变压器是配电系统中的核心设备，其运行状态直接关系到供电可靠性、电能质量以及企业安全生产水平。随着城网改
造、工业负荷增长和配网自动化水平不断提升，传统以周期性停电检修为主的管理模式已难以适应当前设备精益化运维要求。本文立足一
线运行检修实践，围绕高压配电变压器常见故障类型、诱发机理、状态评估方法及检修实施技术展开系统研究。首先分析绕组、绝缘、套
管、分接开关、油系统及冷却附件等部位的典型故障表现；其次结合温度、油色谱、绝缘试验、局部放电、负荷变化和在线监测数据，构
建面向现场应用的状态诊断思路；再次提出以风险分级、趋势预警、缺陷闭环和差异化检修为核心的状态检修技术路径；最后结合表格数
据对故障特征及检修成效进行归纳。研究表明，实施状态检修能够有效降低突发故障率，缩短停电时间，提高设备全寿命周期管理水平。</p>