        <p>大体积基础底板混凝土施工中，水泥水化热引起的温度应力是产生裂缝的主要原因，直接影响基础结构的整体性和防水性能。
本文结合多地区某超高层项目 3.5m 厚基础底板施工实践，系统分析了大体积混凝土温度裂缝产生机理，从配合比优化、分段跳仓浇筑组织、
智能化温度监测、动态保温养护四个方面提出了一整套温控防裂技术措施。通过"分段分层、内散外蓄"的施工方法，结合无线测温系统 24
小时实时监控，将混凝土内外温差稳定控制在 25℃以内，降温速率控制在 2℃/d 以内，成功实现了 1.2 万立方大体积混凝土一次性浇筑无
可见裂缝，经检测未发现任何有害裂缝，为同类超厚基础施工提供了可借鉴的经验。</p>